ED-MONITOR-116C Hardware Revision History
1 ED-MONITOR-116C Rev001 Version
Introduce the detailed information of the ED-MONITOR-116C Rev001 version.
TIP
ED-MONITOR-116C unit is equipped with the ED-MIB-HTLE-A mainboard, where ED-MONITOR-116C Rev001 corresponds to the ED-MIB-HTLE-A Rev001 mainboard.
1.1 Version Overview
- Version Number: Rev001
- Release Date: 2025-03-29
- Release Type: Stable Release
1.2 Version Description
Initial Release
1.3 Fixed Issues
None
1.4 Known Issues
None
2 ED-MONITOR-116C Rev002 Version
Introduce the detailed information of the ED-MONITOR-116C Rev002 version.
TIP
ED-MONITOR-116C unit is equipped with the ED-MIB-HTLE-A mainboard, where ED-MONITOR-116C Rev002 corresponds to the ED-MIB-HTLE-A Rev002 mainboard.
2.1 Version Overview
- Version Number: Rev001
- Release Date: 2025-05-24
- Release Type: Stable Release
2.2 Version Description
Power compatibility upgrade
2.3 New Function
None
2.4 Optimization
The power input has been changed from 12V DC to 24V DC to better meet the requirements of industrial applications.
2.5 Fixed Issues
None
2.6 Known Issues
None
3 ED-MONITOR-116C Rev003 Version
Introduce the detailed information of the ED-MONITOR-116C Rev003 version.
TIP
ED-MONITOR-116C unit is equipped with the ED-MIB-HTLE-A mainboard, where ED-MONITOR-116C Rev003 corresponds to the ED-MIB-HTLE-A Rev003 mainboard.
3.1 Version Overview
- Version Number: Rev001
- Release Date: 2026-11-05
- Release Type: Stable Release
3.2 Version Description
- Upgrade product structure
- Optimize power input circuit
3.3 New Function
Add a surge suppression protection circuit at the power input to effectively suppress inrush current during hot-plugging, reduce the risk of board damage, and improve equipment reliability.
3.4 Optimization
- The color of the chassis fixing screws was changed from black to silver, improving the product's ESD immunity performance and enhancing equipment reliability.
- Optimize the power supply system and grounding strategy to improve equipment reliability.
3.5 Fixed Issues
- Fixed the issue where the left and right audio channels were reversed when headphones were connected to the audio jack.
- Fixed the issue where the device backlight could not be completely turned off under 24V power input (including abnormal display such as screen graying and red/green/blue cycling).
3.6 Known Issues
None